Our standard Fast Loop filters are constructed from 316L stainless steel. A straight through flow design continuously flushes the filter element carrying the contaminates back out to the process stream, thus maximizing the filter element life. The low flow sample stream pulled into the analyzer is filtered to ranges of 200 micron to 0.5 micron (depending on the filtration efficiency required). Traditional T-type by-pass filters are detailed under Analyzer Filters.
The Fast Loop filters use axial velocity to flush heavy contaminates down stream while passing the sample through the element wall with low flow radial velocity. The annular cavity is filled and the sample passes into the sample line. Our 127IL-3 has an offset sample port for even more sweeping action and is available with (standard) 1/4” or 1/2” ports. The annular cavity has very low volume to minimize lag time and keep the samples clean. For best results, a minimum of a 4 to 1 flow rate should be maintained for continuous flushing.
|
|
PRINCIPLE SPECIFICATIONS
| Housing Model |
126IL-3 |
127IL-3* |
136IL-3 |
146IL-3 |
|
Inline Port Size
Sample Port Size
Maximum
Temperature (°F)
Maximum Pressure (PSIG)
|
1/4”
1/4”
400
5000 |
1/4”
1/4”
400
5000 |
1/2”
1/4”
400
1500 |
1/2”
1/4”
400
1500 |
|
PTFE Model (1)
Standard
Viton O-Ring
Optional
Kalrez O-Ring |
126PIL-3
GV126IL-3
KZ126IL-3 |
127PIL-3
GV127IL-3
KZ127IL-3 |
136PIL-3
GV136IL-3
KZ136IL-3 |
146PIL-3
GV136IL-3
KZ136IL-3 |
|
Principal
Dimensions: (inches)
Center of Port to Head
Head
Diameter
Overall
length
Element
Removal Clearance
Element
size |
1.89”
1.97”
3.78”
2.95”
1/2" x 2 1/4" |
1.77”
1.81”
6.89”
“
1/2" x 5” |
2.24”
2.50”
4.49”
3.35”
1” x 2 1/2” |
4.49”
2.50”
9.13”
7.87”
1” x 7” |
|
Filter Element
Codes: (2)
Stainless
Steel Element
PTFE
Element
PEL
Element |
SS-12-57-□
PT-12-57-□
PEL-12-57-□ |
SS-127-□
N/A
N/A |
SS-25-64-□
PT-25-64-□
PEL-25-64-□ |
SS-25-178-□
PT-25-178-□
PEL-25-178-□ |
|
Materials
of Construction: (3)
Head, Bowl
& Internals
O-Rings
(Standard) |
316L
Viton |
316L
Viton |
316L
Viton |
316L
Viton |
|
Internal
Volume (cc)
Annular
Volume (cc) |
28
15 |
58
30 |
94
32 |
240
90 |
Note: (1) Maximum temperature on PIL-3 Models 300°F,
maximum pressure is 100 psig, Viton seal standard.
(2) Replace
“□” with
micron required, e.g. SS-25-64-10T
(3) Material Abbreviation, 316L = 316L
Stainless Steel
(*) 127IL-3 comes standard with all
1/4” ports. 127IL-3-1/2”-1/4” has 1/2” inlet/outlet ports, and 1/4” sample.
|
Stainless Steel elements consists of five layers of precision-woven 316L stainless steel mesh formed into cylinders and sintered together; the filter layer being supported, protected and prefilitered by two inner and two outer layers. Five layers offer surface area and depth area for removing solids and dropping out liquids. UFS offers seven standard grades of filtration with a 98% efficiency in the following microns: 01, 03, 10, 25, 50, 100 and 200. Grade 25 (25 micron) is widely used to protect sample flows from visible particulate while grade –03 is recommended for the removal of pipe scale from steam. Non-standard micron sizes are typically sintered elements, such as the 005, (0.5 micron).
PTFE sintered elements are used where sample compatibility is of concern. Three grades of filtration are available with a 98% efficiency: 2, 10 and 25 micron. |
SAMPLE
STREAM WATER FLOW RATES IN GPH (LPM) AT 1.5 PSI DROP
|
Stainless Steel
Micron Size
|
PTFE
Micron Size
|
PEL
Micron Size
|
Housing Model Series |
|
126IL-3
126PIL-3
120
Series
|
127IL-3
|
136IL-3
136PIL-3
130
Series
|
146IL-3
146PIL-3
140
Series
|
|
005 (0.5 micron)
01 (1 micron)
3
10
25
50
100
200
|
--
--
2
10
25
--
--
--
|
--
--
--
10
25
75
--
250
|
2 (.2)
5 (.3)
11 (.7)
26 (1.6)
27 (1.7)
29 (1.8)
33 (2.1)
41 (2.6)
|
4 (0.25)
10 (.6)
20 (1.2)
45 (2.9)
57 (3.6)
63 (4)
65 (4.1)
81 (5.1)
|
5 (.3)
13 (.8)
26 (1.6)
62 (3.9)
84 (5.3)
90 (5.6)
95 (5.9)
118 (7.4)
|
13 (.9)
32 (2)
61 (3.8)
111 (7)
132 (8.3)
140 (8.8)
158 (9.9)
185
(11.7)
|
|
Above flow rates are gallons per hour (liter per minute).
Note: Support cores should not be used with Fast Loop housings 126IL-3, 127IL-3, 136IL-3 and 146IL-3. They should only be used with traditional T-type housings,
Flow rates are generally proportional to pressure drop. If initial pressure drop of 3 psi can be tolerated, then the above flow rate can be doubled. Flow rates are generally inversely proportional to liquid viscosity.