| DISPOSABLE INLINE FILTERS - DIF-MN ("MINI") | | | |
| Mini - Part Number: DIF-MNxx | | | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-MN50 | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 125 PSIG |
| Volume (cc) | 6 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.00 |
| Spigot Length | 0.43 |
| Overall Length | 1.71 |
| Materials of Construction: | | | | | | | | | |
| Body | Nylon | | | | | | | | | |
| Filter Element | K-Type | | | | | | | | | |
| Filter Element Size | 12-16-□ | | | | |
| | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| GAS FLOW RATES - DIF-MN□ (12-16-□) - MINI |
| DIF Model | Filtration Efficiency Removal Of 0.01 | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop |
| Number | Micron Particles | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 125 |
| DIF-MN30 | 99.99998+% | 0.1 | 0.15 | 0.2 | 0.25 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 |
| DIF-MN40 | 99.99998+% | 0.15 | 0.2 | 0.3 | 0.4 | 0.5 | 0.7 | 0.8 | 1.0 | 1.2 |
| DIF-MN50 | 99.99+% | 0.3 | 0.4 | 0.6 | 0.8 | 1.0 | 1.0 | 1.7 | 2.1 | 2.8 |
| DIF-MN60 | 99.5+% | 0.4 | 0.7 | 1.0 | 1.3 | 1.6 | 2.1 | 2.7 | 3.4 | 4.1 |
| DIF-MN70 | 95.0+% | 0.5 | 0.8 | 1.1 | 1.4 | 1.8 | 2.4 | 3.0 | 3.7 | 4.7 |
| DIF-MN80 | 75.0+% | 0.9 | 0.9 | 1.3 | 1.6 | 2.0 | 2.7 | 3.5 | 4.3 | 5.0 |
| | | | | | | | | | |
| | | | | | | | | | |
| LIQUID FLOW RATES - (12-16-□) - MINI |
| DIF Model | Filtration Efficiency 98% Removal | Water Flow Rate |
| Number | Rating | Gallons / Hr at 1.5 PSIG Pressure Drop |
| DIF-MN30 | 0.3 micron | 0.6 |
| DIF-MN40 | 1 micron | 1.6 |
| DIF-MN50 | 2 micron | 3.3 |
| DIF-MN60 | 8 micron | 6.5 |
| DIF-MN70 | 25 micron | 8.0 |
| DIF-MN80 | 75 micron | 8.5 |
| | | | | | | | | | |
Our standard DIF-BN series is by far the most commonly used size of DIF since it combines high efficiency filtration with low pressure drops in a compact package. Whether being used in an OEM cabinet, emission bench, or air monitor this little gem is an economical workhorse.
|
| DISPOSABLE INLINE FILTERS - DIF-BN ("STANDARD") | | |
| Standard - Part Number: DIF-BNxx | | | | | | | | | |
| Kynar Part Number: DIF-BKxx | | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-BN50 | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 125 PSIG |
| Volume (cc) | 11.5 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.00 | |
| Spigot Length | 0.79 |
| Overall Length | 3.23 |
| Materials of Construction: | | | | | | | | | |
| Body | Nylon / Kynar | | | | | | | | | |
| Filter Element | K-Type | | | | | | | | | |
| Filter Element Size | 12-32-□ | | | | | | | | | |
| | | | | | | | | | |
| GAS FLOW RATES - DIF-BN□ (12-32-□) - STANDARD |
| DIF Model | Filtration Efficiency Removal Of 0.01 | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop |
| Number | Micron Particles | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 125 |
| DIF-BN30 | 99.99998+% | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.8 | 1.0 | 1.3 | 1.5 |
| DIF-BN40 | 99.99998+% | 0.3 | 0.4 | 0.7 | 0.8 | 1.0 | 1.4 | 1.7 | 2.1 | 2.5 |
| DIF-BN50 | 99.99+% | 0.6 | 0.9 | 1.3 | 1.6 | 2.0 | 2.7 | 3.5 | 4.2 | 5.7 |
| DIF-BN60 | 99.5+% | 0.9 | 1.4 | 2.0 | 2.6 | 3.2 | 4.3 | 5.4 | 6.9 | 8.2 |
| DIF-BN70 | 95.0+% | 1.1 | 1.6 | 2.3 | 2.9 | 3.6 | 4.9 | 6.0 | 7.5 | 9.4 |
| DIF-BN80 | 75.0+% | 1.2 | 1.8 | 2.6 | 3.3 | 4.0 | 5.5 | 7.0 | 8.6 | 10.0 |
| | | | | | | | | | |
| LIQUID FLOW RATES - (12-32-□) -STANDARD |
| DIF Model | Filtration Efficiency 98% Removal | Water Flow Rate |
| Number* | Rating* | Gallons / Hr at 1.5 PSIG Pressure Drop |
| DIF-BN30 | 0.3 micron | 1.3 |
| DIF-BN40 | 1 micron | 3.2 |
| DIF-BN50 | 2 micron | 6.6 |
| DIF-BN60 | 8 micron | 13.0 |
| DIF-BN70 | 25 micron | 16.0 |
| DIF-BN80 | 75 micron | 17.0 |
| | | | | | | | | | |
| Notes: (*) Use the same flow rates for DIF-BK |
| | | | | | | | | | |
| DISPOSABLE INLINE FILTERS - DIF-IN ("INTERMEDIATE") | | |
| Intermediate - Part Number: DIF-INxx | | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-IN50 | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 50 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.44 |
| Spigot Length | 0.77 |
| Overall Length | 4.61 |
| Materials of Construction: |
| Body | Nylon | | | | | | | | | |
| Filter Element | K-Type | | | | | | | | | |
| Filter Element Size | 12-57-□ | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| Intermediate Coalescer - Part Number: DIF-INxxC | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-IN50C | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | 0.25" |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 50 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.44 |
| Spigot Length | 0.77 |
| Overall Length | 4.61 |
| Materials of Construction: | | | | | | | | | |
| Body | Nylon | | | | | | | | | |
| Filter Element | C-Type | | | | | | | | | |
| Filter Element Size | 12-57-□C | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| GAS FLOW RATES - DIF-IN□ (12-57-□) - INTERMEDIATE | |
| DIF Model | Filtration Efficiency Removal Of 0.01 | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop | |
| Number | Micron Particles | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | |
| DIF-IN30 | 99.99998+% | 0.4 | 0.5 | 0.7 | 0.75 | 0.9 | 1.0 | 1.5 | 2.0 | |
| DIF-IN40 | 99.99998+% | 0.7 | 1.0 | 1.7 | 2.0 | 2.7 | 3.3 | 4.1 | 5.0 | |
| DIF-IN50 | 99.99+% | 1.5 | 2.1 | 3.4 | 4.0 | 5.3 | 6.6 | 8.3 | 10.0 | |
| DIF-IN60 | 99.5+% | 3.0 | 4.4 | 7.0 | 8.4 | 11.2 | 14.0 | 17.5 | 21.0 | |
| DIF-IN70 | 95.0+% | 3.6 | 5.2 | 8.4 | 10.0 | 13.5 | 17.0 | 21.5 | 26.0 | |
| DIF-IN80 | 75.0+% | 4.0 | 5.8 | 9.3 | 11.0 | 15.0 | 19.0 | 24.0 | 29.0 | |
| | | | | | | | | | |
| | | | | | | | | | |
| LIQUID FLOW RATES - (12-57-□) -INTERMEDIATE | |
| DIF Model | Filtration Efficiency 98% Removal | Water Flow Rate | |
| Number | Rating | Gallons / Hr at 1.5 PSIG Pressure Drop | |
| DIF-IN30 | 0.3 micron | 2.6 | |
| DIF-IN40 | 1 micron | 6.4 | |
| DIF-IN50 | 2 micron | 13.2 | |
| DIF-IN60 | 8 micron | 26.0 | |
| DIF-IN70 | 25 micron | 32.0 | |
| DIF-IN80 | 75 micron | 34.0 | |
| | | | | | | | | | |
| DISPOSABLE INLINE FILTERS - DIF-LN ("LARGE") | | |
| Large - Part Number: DIF-LNxx | | | | | | | | | |
| Kynar Part Number: DIF-LKxx | | | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-LN50 | | |
| Inlet / Outlet: | 1/4" NPT | |
| Drain Connection | None |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 120 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.50 |
| Body Diameter | 2.28 |
| Spigot Length | 1.05 |
| Overall Length | 5.43 |
| Materials of Construction: |
| Body | Nylon / Kynar | | | | | | | | | |
| Filter Element | K-Type | | | | | | | | | |
| Filter Element Size | 25-64-□ | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| Large Coalescer - Part Number: DIF-LNxxC | | | | | | | | |
| Kynar Part Number: DIF-LKxxC | | | | | | | |
| Replace "xx" with grade required 30, 40, 50, 60, 70, 80, e.g. DIF-LN50C | | |
| Inlet / Outlet: | 1/4" NPT | |
| Drain Connection | 0.30" |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 120 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.50 |
| Body Diameter | 2.28 |
| Spigot Length | 1.05 |
| Overall Length | 5.43 |
| Materials of Construction: |
| Body | Nylon / Kynar | | | | | | | | | |
| Filter Element | C-Type | | | | | | | | | |
| Filter Element Size | 25-64-□C | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
Notes: (1) 1/4 MNPT (Threads) = 1/2 OD which can accommodate 1/2 ID tubing. If threads are not desired order as DIF-LN60-SlipOn
|
| GAS FLOW RATES - DIF-LN□ (25-64-□) - LARGE | |
| DIF Model | Filtration Efficiency Removal Of 0.01 | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop | |
| Number | Micron Particles | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | |
| DIF-LN30 | 99.99998+% | 0.7 | 1.0 | 1.5 | 2.0 | 2.5 | 3.2 | 4.1 | 5.1 | |
| DIF-LN40 | 99.99998+% | 1.2 | 1.8 | 2.6 | 3.2 | 4.0 | 5.5 | 7.2 | 8.0 | |
| DIF-LN50 | 99.99+% | 2.4 | 3.6 | 5.1 | 6.3 | 7.9 | 11.0 | 14.0 | 17.0 | |
| DIF-LN60 | 99.5+% | 3.8 | 5.9 | 8.3 | 10.0 | 13.0 | 17.0 | 22.0 | 26.0 | |
| DIF-LN70 | 95.0+% | 4.3 | 6.4 | 9.3 | 12.0 | 14.0 | 19.0 | 24.0 | 30.0 | |
| DIF-LN80 | 75.0+% | 4.7 | 6.9 | 10.0 | 13.0 | 16.0 | 22.0 | 27.0 | 34.0 | |
| | | | | | | | | | |
| LIQUID FLOW RATES - (25-64-□) -LARGE | |
| DIF Model | Filtration Efficiency 98% Removal | Water Flow Rate | |
| Number* | Rating* | Gallons / Hr at 1.5 PSIG Pressure Drop | |
| DIF-LN30 | 0.3 micron | 13.0 | |
| DIF-LN40 | 1 micron | 26.0 | |
| DIF-LN50 | 2 micron | 62.0 | |
| DIF-LN60 | 8 micron | 84.0 | |
| DIF-LN70 | 25 micron | 95.0 | |
| DIF-LN80 | 75 micron | 118.0 | |
Notes: (*) Use the same flow rates for DIF-BK
DISPOSABLE INLINE FILTERS & ADSORBERSOur Disposable In-Line Adsorbers consist of nylon or kynar bodies filled with granular adsorption material with integral inlet and outlet filter pads. For best results, the longer the contact time, the more effective the adsorbers will be. Choose the appropriate adsorbent for your application from the list below. Our Disposable In-Line Adsorbers consist of granular adsorbent material ultrasonically welded into a see-through nylon or kynar body. Integral filter pads eliminate adsorbent migration. Four sizes are available, containing from 6cc up to 120cc of adsorbent.
|
| | | | | | | | | | |
| DISPOSABLE INLINE ADSORBERS - DIA-MN ("MINI") | |
| Mini - Part Number: DIA-MNxx | | | | | | | | | |
| Replace "xx" with grade required CC, 4A, 13X, SG, DR, MB, PP, HO, SB, CS, e.g. DIA-MNCC | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 125 PSIG |
| Volume (cc) | 6 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.00 |
| Spigot Length | 0.43 |
| Overall Length | 1.71 |
| Materials of Construction: | | | | | | | | | |
| Body | Nylon | | | | | | | | | |
| Adsorbent | Specify Adsorbent | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| GAS FLOW RATES - DIA-MN□ - MINI |
| DIA Model Number | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop |
| | | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 125 |
| DIA-MNxx | 0.3 | 0.4 | 0.6 | 0.8 | 1.0 | 1.3 | 1.7 | 2.1 | 2.8 |
| | | | | | | | | | |
| | | | | | | | | | |
| DISPOSABLE INLINE ADSORBERS - DIA-BN ("STANDARD") | | |
| Standard - Part Number: DIA-BNxx | | | | | | | | | |
| Kynar Part Number: DIA-BKxx | | | | | | | | |
| Replace "xx" with grade required CC, 4A, 13X, SG, DR, MB, PP, HO, SB, CS, e.g. DIA-BNCC | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 125 PSIG |
| Volume (cc) | 11.5 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.00 |
| Spigot Length | 0.79 |
| Overall Length | 3.23 |
| Materials of Construction: | | | | | | | | | |
| Body | Nylon / Kynar | | | | | | | | | |
| Adsorbent | Specify Adsorbent | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |
| GAS FLOW RATES - DIA-BN□ - STANDARD |
| DIA Model Number | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop |
| | | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 125 |
| DIA-BNxx | 0.6 | 0.9 | 1.3 | 1.6 | 2.0 | 2.7 | 3.5 | 4.2 | 5.7 |
| Notes: (*) Use the same flow rates for DIF-BK |
| | | | | | | | | | |
| DISPOSABLE INLINE ADSORBERS - DIA-IN ("INTERMEDIATE") | | |
| Intermediate - Part Number: DIA-INxx | | | | | | | | |
| Replace "xx" with grade required CC, 4A, 13X, SG, DR, MB, PP, HO, SB, CS, e.g. DIA-INCC | | |
| Inlet / Outlet: | 0.25" | |
| Drain Connection | None |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 50 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.25 |
| Body Diameter | 1.44 |
| Spigot Length | 0.77 |
| Overall Length | 4.61 |
| Materials of Construction: |
| Body | Nylon |
| Adsorbent | Specify Adsorbent |
|
| | | | | | | | | | |
| GAS FLOW RATES - DIA-IN□ - INTERMEDIATE | |
| DIA Model Number | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop | |
| | | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | |
| DIA-INxx | 1.5 | 2.1 | 3.4 | 4.0 | 5.3 | 6.6 | 8.3 | 10.0 | |
| | | | | | | | | | |
| DISPOSABLE INLINE ADSORBERS - DIA-LN ("LARGE") | | |
| Large - Part Number: DIA-LNxx | | | | | | | | | |
| Kynar Part Number: DIA-LKxx | | | | | | | | | |
| Replace "xx" with grade required CC, 4A, 13X, SG, DR, MB, PP, HO, SB, CS, e.g. DIA-LNCC | | |
| Inlet / Outlet: | 1/4" NPT | |
| Drain Connection | None |
| Maximum Pressure | 100 PSIG |
| Volume (cc) | 120 |
| Maximum Temperature: |
| °F At 0 PSIG | 230 |
| °F At 100 PSIG | 120 |
| Principle Dimensions: (Inches) |
| Spigot Diameter | 0.50 |
| Body Diameter | 2.28 |
| Spigot Length | 1.05 |
| Overall Length | 5.43 |
| Materials of Construction: |
| Body | Nylon / Kynar | | | | | | | | | |
| Adsorbent | Specify Adsorbent | | | | | | | | | |
Notes: (1) 1/4 MNPT (Threads) = 1/2 OD which can accommodate 1/2 ID tubing. If threads are not desired order as DIA-LNCC-SlipOn
|
| GAS FLOW RATES - DIA-LN□ - LARGE | |
| DIA Model Number | Gas Flow In SCFM At Stated Line Pressure In PSIG And 1.5 PSIG Pressure Drop | |
| | | 1.5 | 10 | 20 | 30 | 40 | 60 | 80 | 100 | |
| DIA-LNxx | 2.4 | 3.6 | 5.1 | 6.3 | 7.9 | 11.0 | 14.0 | 17.0 | |
| Notes: (*) Use the same flow rates for DIF-LK |